Technical project enquiries
Architectural lighting alternatives, reviewed against your specification
A successful alternative preserves design intent—not just appearance or wattage. Share the original reference, installation conditions and required performance. Any proposed configuration needs a documented comparison and acceptance by the responsible project team.
Evidence before equivalence
01
Potential option for technical review
Correct category, mounting and use; all known gaps disclosed.
02
Compared against stated project requirements
Signed comparison, exact configurations, photometry, drawings, controls, environment and warranty review.
03
Accepted for this project and revision
Named consultant/client acceptance, sample or mock-up where required, schedule and recorded deviations.
Electrical safety, mounting, environment and required approvals are stop conditions. No similarity score can compensate for a failed gate. No manufacturer affiliation, blanket equivalence or project acceptance is implied.
Identity and installation
- Reference brand / model / revision
- Proposed LUMIBRIGHT configuration
- Mounting and installation kit
- Cut-out / aperture / recess depth
- Adjustment / weight / accessories
Photometric performance
- System watts and delivered lumens
- Exact optic / CCT IES or LDT revision
- Peak intensity / beam axes / field angle
- Same-geometry illuminance / uniformity
- Glare assumptions
Colour and comfort
- CCT / tolerance
- CRI Ra / R9
- TM-30 Rf / Rg / SDCM
- Dimming behaviour
- Shielding and visual appearance
Electrical and controls
- Input / output / driver code
- Current / voltage / load
- Control protocol and dimming range
- Flicker test conditions
- Emergency / control compatibility / commissioning
Environment and durability
- Installed IP / IK
- Ta / thermal limits
- Material / coating / corrosion evidence
- Surge protection
- LxBy lifetime conditions / maintainability
Commercial and assurance
- Included / required / optional BOM
- Quantity / price basis / exclusions
- Sample and lead-time confirmation
- Warranty eligibility / policy / territory
- Accepted deviations and project approval
Request a technical alternative