Outdoor lighting showcase

Application

Outdoor

Landscape illumination creating safe, beautiful spaces

IP65+ weather protectionPrecise beam controlEnergy-efficient LEDLow light pollution

ZONE 01 - FACADE WALL GRAZING

Facade Wall Grazing

Reveal architectural texture and form

Outdoor - Facade Wall Grazing lighting environment

Precision wall-grazing optics illuminate stone and concrete textures. Warm 3000K emphasizes material richness at night. Minimal light spill and dark-sky compliance protect the nocturnal environment while creating signature building identity.

Vertical Illuminance: 50-150 lux on facadeCCT: 3000K warmIP Rating: IP65, IK08

  • Texture emphasis
  • Building identity
  • Low light pollution

ZONE 02 - PATHWAYS

Pathways

Ensure safe pedestrian navigation

Outdoor - Pathways lighting environment

Low-level bollard lighting provides glare-controlled wayfinding. Warm 2700K creates a welcoming, human-scale environment. Desert plants receive subtle uplighting for visual interest without overwhelming the night sky.

Path Illuminance: 20-50 luxCCT: 2700K warmGlare Control: Shielded sources, UGR <28

  • Pedestrian safety
  • Welcoming
  • Energy efficiency

ZONE 03 - PARKING

Parking

Deliver uniform safety illumination

Outdoor - Parking lighting environment

High-uniformity area lighting ensures safe vehicle and pedestrian movement. Neutral 4000K supports visibility and security. Minimal glare and robust construction withstand outdoor conditions.

Illuminance: 20-75 lux horizontalCCT: 4000K neutralIP Rating: IP65, IK10 vandal-resistant

  • Security
  • Safety
  • Energy management

ZONE 04 - CANOPY

Canopy

Create welcoming drop-off zones

Outdoor - Canopy lighting environment

Concealed linear luminaires integrated into hotel drop-off canopies provide uniform, glare-free illumination. Warm 3000K creates a welcoming first impression. Recessed mounting preserves clean architectural lines.

Illuminance: 100-200 lux at groundCCT: 3000K warmIP Rating: IP65

  • Welcoming arrival
  • Safety
  • Architectural integration

ZONE 05 - PUBLIC PLAZA

Public Plaza

Layer landscape and architectural lighting

Outdoor - Public Plaza lighting environment

Layered outdoor lighting creates depth and drama-step lights define edges, tree uplights add vertical interest, soft ambient glow unifies the space. Warm 3000K creates inviting public spaces after dark.

Ambient: 20-50 luxAccent: Tree uplights, step lightsCCT: 3000K warm

  • Public safety
  • Placemaking
  • Visual hierarchy

Technical Specifications & Performance

Comprehensive technical data for specification professionals

Photometrics & Performance

Technical lighting performance specifications for specification professionals

CCT Range2700K - 5000K Tunable

Kelvin

Color RenderingCRI 90+, TM-30 Rf ≥85

Index

Glare ControlUGR <19

Unified Glare Rating

Flicker PerformancePstLM <1%, SVM <0.4

IEEE 1789

Lifetime RatingL90 > 50,000 hrs

Hours

Controls & Interoperability

Compatible with industry-standard lighting control protocols for seamless building integration

DALI-2
0-10V Dimming
KNX Integration
Casambi
Bluetooth Mesh

Sustainability & Support

Environmental compliance and comprehensive service for UAE projects

Sustainability & Compliance

Environmental responsibility and regulatory compliance for responsible specification

RoHS/REACH

Compliant with EU chemical safety directives

ISO 9001/14001

Quality and environmental management certified

LEED/WELL Aligned

Contributes to green building certification points

EPD Available

Environmental Product Declaration on request

Warranty, supply and project support

Confirm the written warranty eligibility, territory, component coverage and installation conditions for the exact product codes. Local stock, lead times, support scope and response arrangements must be agreed for the project.

Industry Standards & Certifications

LumiBright solutions align with international lighting standards and building certification programs

Technical Documentation Hub

Download complete technical packages for Outdoor lighting specification

IES/LDT Files

Photometric data for lighting calculations

IES, LDT

Revit Families

BIM objects for architectural integration

RFA, RVT

Datasheets & Cut Sheets

Complete product specifications and dimensions

PDF

Installation Guides

Technical installation and commissioning instructions

PDF

Featured Products for Outdoor

Curated lighting solutions engineered for outdoor environments

Ready to Specify?

Our lighting consultants are available to support your outdoor project with technical guidance, photometric analysis, and specification documents.

Design criteria

Lighting for building façades and architectural features

Façade lighting is an optics and control problem before it is a lumen problem. The brief is usually to reveal a material or a line - stone texture, a colonnade, a parapet - without spilling light into rooms, onto neighbours or into the sky. That means grazing or narrow-beam optics, precise aiming and accessories, ingress and corrosion protection matched to the Gulf climate, and a control layer that can hold a curfew setting.

Grazing stone / textureMount close to the wall (50-150 mm) so the beam rakes the texture.IlluminanceAim for 20-50 lx on the surfaceUniformityDeliberately gradedColourCRI 80-90GlareClose offset, shieldedCCT2700-3000K
Wall washing (flat surface)Space fittings at roughly the mounting offset x 1-1.5 for an even wash.Illuminance30-75 lx on the surfaceUniformityUo >= 0.5 visually evenColourCRI 80-90GlareAsymmetric opticCCT3000K
Feature / tree uplightIP67/IP68 in-ground, drained and rated for the load it sits in.IlluminanceContrast-drivenUniformity—ColourCRI 80+GlareSnoot or honeycomb, full cut-offCCT3000K (4000K for foliage)
Colour-change / media façadeFix the protocol (DMX/RDM or DALI) and the pixel pitch before selecting the fitting.IlluminanceProject-specificUniformity—Colour—GlareAim below sightlinesCCTRGBW
Sky glow / obtrusive lightCIE 150 and local authority limits govern spill, glare and curfew hours.IlluminanceFollow local curfew limitsUniformity—Colour—GlareUpward light ratio as low as the detail allowsCCT2700-3000K

Illustrative project-brief ranges, not measured model performance or universal code requirements. Confirm the relevant task, standard edition, site conditions and local requirements.

How to specify

Five decisions that set the fitting

  1. Decide what the light is revealing - texture, plane, edge or silhouette - then choose grazing, washing, narrow-beam or linear optics accordingly.
  2. Specify IP65 as a minimum, IP66/IP67 where jet-washing or flooding is possible and IP68 for submerged or in-ground positions.
  3. Check the finish and fixings against the microclimate: coastal salt spray needs marine-grade stainless or a qualified coating system.
  4. Confirm IK rating and accessory options (snoots, louvres, glare shields) where the public can reach or see the fitting.
  5. Agree a curfew scene with the client so the scheme meets obtrusive-light limits after a set hour.

Specify from

Candidate families for technical review

618 articles across 12 families

Specifier questions

Frequently asked

How far from the wall should a grazing fitting sit?

50 to 150 mm for texture grazing. Further out and the beam flattens; too close and the first 300 mm of wall is over-lit. The detail should also allow for drainage and maintenance access.

What IP rating do in-ground uplights need?

IP67 as a minimum and IP68 where the recess can flood or sit under irrigation. Check the drainage detail as well as the rating - standing water plus heat is what kills in-ground fittings.

Can I use warm white on stone and 4000K on planting?

Yes, and it usually reads well: 2700-3000K keeps limestone and sandstone warm, while 4000K makes foliage look greener. Keep each material consistent.

DMX or DALI for a façade?

DMX/RDM where the scheme is pixel-addressed or colour-changing; DALI-2 where it is static white with scenes and is tied into the building system. Decide before the fitting so the driver matches.